FWB
Tool
InsECT
FWB
Settings
Info
About InsECT
Terms of use
Requirements
Privacy
Changelog
Manual
Imprint
Language
German
English
Pumping rate calculation based on measurements with:
BAUMX7 Polyglycol FKM
BAUX2 Polyglycol NBR
BAUX2 Polyalphaolefin oil NBR
BAUMX7 Mineral oil FPM/FKM
BAUMX7 Polyalphaolefin oil FKM
BAFUDX7 Mineral oil NBR
Testdichtring FVA NBR
Operating conditions
shaft diameter [mm]:
mean roughness depth Rz [μm]:
circumferential speed [m/s]:
dynamic viscosity [mPa·s]:
Calculate!
Reset input parameters
Results
Pumping rate per distance unit ≈ 0,286 [μl/m]
Pumping rate per revolution ≈ 0,007 [μl/U]
Pumping rate per time unit ≈ 5,141 [ml/h]
You can download a report containing your calculation results as a pdf file.
Download report