shaft speed [rpm]:

   

shaft diameter [mm]:
relative fluid fill level [%]:
fluid sump temperature [°C]:
thermal conductivity of shaft [W/(m·K)]:
temperature of the ambient air [°C]:
radial load (at ambient temperature) [N]:

   

temperature coefficient [N/K]:

   

contact width [mm]:
Guembel curve coefficient A₁ [-]:

   

Guembel curve coefficient A₂ [-]:

   

Guembel curve coefficient A₃ [-]:

   

frictional heat [W]:

   

fluid type: Mineral oil
density (at 15 °C) [kg/m³]:

   

temperature of 1st viscosity [°C]:
1st kinematic viscosity [mm²/s]:
temperature of 2nd viscosity [°C]:
2nd kinematic viscosity [mm²/s]:
thermal conductivity (at 15 °C) [W/(m·K)]:

   




Results
temperature rise ≈ 31,4 K
contact temperature ≈ 111,4 °C
circumferential speed ≈ 12,6 m/s
thermal resistance ≈ 79,79 m·K/W

You can download a report containing your calculation results as a pdf file.